About 76,500 results
Open links in new tab
  1. Introduction to Modbus and Modbus Function Codes

    Jan 30, 2023 · Introduction to Modbus and Modbus Function Codes Modbus is one of the oldest industrial communication protocols still in use today. Continue reading to find out how the protocol …

  2. Modbus client application | Automation & Control Engineering Forum

    Jan 9, 2024 · Open Modbus adds two other IEEE754 32 bit floating formats with its LE button which selects between Big Endian and Little Endian. Win-tech two standard FP formats correspond to the …

  3. Modbus TCP - What is the correct usage of Unit ID?

    Jan 26, 2012 · The unit ID is used when dealing with Modbus Bridges. Typical bridges convert Modbus TCP to Modbus serial or Modbus plus. The Unit ID is either the device Id of serial device or it is index …

  4. Modbus Time Out Error | Automation & Control Engineering Forum

    Aug 12, 2019 · Modbus slaves can not initiate a transaction - cannot send on their own. The problem could be almost anything - Devices must be Modbus enabled. Just because a device has a serial …

  5. Modbus over Ethernet | Automation & Control Engineering Forum

    Jun 25, 2008 · Modbus is a protocol. You can use Modbus protocol over Ethernet, it is then called Modbus TCP/IP. Commonly used by Schneider Electric, as Schneider bought the company Modicon, …

  6. Modbus Exception Code 04 | Automation & Control Engineering Forum

    Aug 3, 2007 · I try to communicate CP341 with modbus rtu slave but the response at the funcion code 05 or 15 is always exception code 04. what kind of error is this?? anybody know ???

  7. Timeout error | Automation & Control Engineering Forum

    Feb 10, 2025 · Modbus Poll is a Modbus master simulator. If your ESP32 is indeed a master, then this won't work, as a Modbus master cannot communicate to another Modbus master.

  8. Confused: Modbus TCP vs. Modbus RTU Over TCP - Control.com

    May 19, 2011 · Modbus RTU over TCP/IP is typically used by serial servers where you can have an Modbus Ethernet client communicating with multiple Modbus RTU- RS485 slaves, by way of a serial …

  9. Modbus TCP cable | Automation & Control Engineering Forum

    Jan 15, 2025 · Hello, Is it possible to run Modbus TCP protocol if cable lenght is 130-140m? It will work if I use cat6 instead of cat5? do you have experience with that?

  10. Modbus Coil and register Question - Control.com

    Dec 31, 2008 · The Modbus "registers" are just data values in the slave (server). Section 4.3 (MODBUS Data model) in the "MODBUS Application Protocol Specification V1.1b" discusses this point. If you …